Enhancements:
The AV UI provides the following enhancements:
- Support
for new profiles:
- DICENTIS
Conference system profile
- Telos
Alliance / Livewire+ AES67
- Support
for configurable colors on the Audio Technica profile.
- Support
for the coexistence of a PTP boundary clock and a transparent clock
on an Auto-Trunk interface.
The firmware provides the following enhancements:
- Supports
four new models M4350-8M2V (MSM4310), M4350-24M4X4V (MSM4332), M4350-24F4X
(MSM4328F) & M4350-40F4C (XSM4344FC).
- Support
for the following new MIB objects:
- agentPortSpeedDuplexStatus: Enables configuration of
port speed and duplex settings. This function is added as OID
“1.3.6.1.4.1.4526.10.1.2.13.1.56” under “agentPortConfigTable”
in “fastpathswitching.my”.
- boxServicesFanControlMode: Allows adjustment of fan
control modes including off, quiet, cool, and auto. This function is
added as OID “1.3.6.1.4.1.4526.10.43.1.21” in ‘boxServicesGroup’
in “fastpath_boxservices.my”.
- agentDot1qPortAcceptableFrameTypes:
Specifies admissible Ethernet frame types for VLAN ports. This function
is added as OID “1.3.6.1.4.1.4526.10.1.2.8.50.1.2” under
“agentDot1qPortVlanTable” in “fastpathswitching.my”.
- Support
for enforcing password reset upon initial login for newly created users.
- Support
for minimum password complexity to comply with NETGEAR password policy.
Bug Fixes:
This firmware addresses the following bugs:
- Fixes
the issue where the maximum response time in general query is not correct.
[MS-4382]
- Fixes
the issue where OSPFv3 packets are not forwarded when IGMP and MLD
snooping are both enabled. [MS-4499]
- Fixes the issue where the switch crashes when a large
configuration file is loaded and clears the configuration. (MS-4655]
- Fixes
the issue where three 40-port models stop booting after upgrading from
firmware 14.0.2.23. [CE-4839]
- Fixes
the issue where the MCU version is shown different in “show hardware” and
“show switch detail” commands. [MS-4851]
- Fixes
the issue where the switch responds to a DHCP request even though no DHCP
pool is created for the subnet. [CE-6246]
- Fixes
the issue where SNMP OID “LastQuerierAddress”
shows an IP address of “0.0.0.0”. [CE-6473]
- Fixes
the issue where the IGMP Operational Mode status, until IP IGMP, displays
as off, then on. [CE-6483]
- Fixes
the issue where the switch models M4350-24X8F8V (XSM4340V), M4350-36X4V
(XSM4340CV) or M4350-32F8V (XSM4340FV), do not boot up when firmware is
upgraded from version 14.0.2.23 and boot code version 1.0.0.8 to the newer
release. [CE-6494]
This AV UI addresses the following bugs:
- Fixes
the issue where the MTU reverts to 9198 after reboot. [CE-6514]
- Fixes
the issue where the PTP TC configuration does not save in the startup
configuration of the AV UI. [CE-6481]
- Fixes
the issue where the AV UI does not restore the configuration with special
characters. [CE-6558]
Known Issues:
This firmware contains the following known issues:
- Auto-LAG
does not form anymore if ‘PTP over Auto-Lag’ is selected.
Workaround: Don’t use ‘PTP
over Auto-Lag’
- The
four 25G ports of models M4350-44M4X4V, M4350-24X4V, and M4350-24F4V can
operate at either 10G or 25G speed but not simultaneously at 10G and 25G
speed.
- A
stacking link works only at the highest speed that the port supports. For
example, if you configure a 25G port in stack mode, the port can operate
only at 25G and not at 10G. Therefore, you cannot establish a stacking
link if a 10G port and a 25G port are interconnected.
General Information:
- The
boot code remains at the existing version 1.0.0.15 in this switch
firmware.
- AppMgr is upgraded to version 1.0.3.26 in this switch
firmware.
- Insight
and Engage/AV UI are mutually exclusive. This
means you can only use one of these options to configure and manage the
switch, not both.
Download Link: https://www.downloads.netgear.com/files/GDC/M4350/M4350_V14.0.6.9.zip
Firmware Update Instructions:
To update your product’s firmware, follow the instructions
in your product’s user manual. To find your user manual, visit https://www.netgear.com/support/, enter
your model number in the search box, and click