Release Date:
April 29, 2026
Enhancements:
The AV UI provides the following enhancements:
- Support
for the AJA AV Network profile.
- Support
for the Audio Video AVB MILAN profile.
- Support
for the Audio Video AVB MILAN with Dante PTPv1 PTPv2 or AES67 profile.
- Support
for the AUDAC Audio and Control Network profile.
- Support
for the BluOS AV profile.
- Support
for the Shure Converged Profile on M4350 switches.
- Support
for the Color Palettes to the profile color picker.
- Updated
the Nice Home Management profile with auto provision features.
- Updated
the Audio Video SMPTE profile description to supported
new M4350 switch models.
Bug Fixes:
This firmware addresses the following bugs:
- Fixes the
issue where only five Auto-LAGs were created even when more than five
devices were connected using multiple links per device. [MS-5200]
- Fixes the
issue where continuous DHCPv6 packets cause the switch to reboot
unexpectedly. [CE-7265]
- Fixes the
issue where the switch operates as dot1AS Grand Master sent Announce
messages with a UTC Offset value of 0. [MS-5416]
- Fixes the
issue where OUI-based VLAN assignments stopped functioning after extended
operation. [CE-7316]
- Fixes an
issue where the VLAN 1 routing interface could not be removed through the
Main UI. [CE-7321]
- Fixes the
issue where PTP time jumped forward intermittently on the M4350-16V4C when
operating as PTP Grand Master. [CE-7349]
- Fixes the
issue where creating a Tagged VLAN Port in an AVB
VLAN Profile incorrectly changes the MTU to 9198. [CE-7632]
- Fixes the issue where PTP TC is not enabled on a manual
LAG interface when using Manual Trunk. [CE-7608]
- Fixes the
issue where the Audio Dante profile auto-trunk port retains “no spanning
tree port mode” configuration after connecting. [PV-6886]
- Fixes the
issue where AVUI rejects subnet mask 255.255.255.254 with an incorrect
subnet error. [CE-7650]
- Fixes the
issue where the PoE++ (802.3bt) option is missing in Engage/ProAV UI for MSM4332, causing ports to be downgraded
to PoE+. [CE-7686]
- Fixes the
issue where NVX profile cannot be applied to ports 25-48 of the secondary
switch in a stacked GSM4352PS configuration. [CE-7512]
- Fixes the
issue where PVST is disabled on a VLAN after deleting and re-creating a
DICENTIS Conference System profile on that VLAN. [CE-7469]
- Fixes the
issue where Voice VLAN configuration on a port was unexpectedly disabled
after re-enabling Insight management. [CE-7582]
- Fixes the
issue where VLAN 1 membership unexpectedly changed to tagged after
activating Insight management. [CE-7601]
AV UI Known Issues:
This update contains the following known issues:
- gPTP Clock Master Causes Time Drift with AVB MILAN
Devices:
If the switch becomes the gPTP clock master,
time drift issues may occur when AVB MILAN devices are in use.
Workaround: When
creating an "Audio Video AVB MILAN" profile in AVUI, set the Local
Clock Priority 1 and Priority 2 values to 255 to prevent the switch from acting
as the clock master.
- Stale
Spanning Tree Configuration After Firmware Upgrade from AVUI 2.2.13.29:
When upgrading firmware from AVUI 2.2.13.29 to the current release, access
port configurations with no spanning-tree port mode may persist. If Dante
devices are connected using redundancy ports, this can cause a network
loop.
Workaround: Manually
clear the stale configuration by setting the affected interfaces back to
spanning-tree port mode.
- Kramer AV
Single-VLAN Profile Cannot Be Modified When Using VLAN 1:
If a Kramer AV profile is created with a single VLAN and that VLAN is VLAN
1, the profile cannot be modified to another single-VLAN profile.
Workaround:
Use a VLAN ID other than VLAN 1 when creating a single-VLAN Kramer AV profile.
Firmware Known Issues:
This firmware contains the following known issues:
- Auto-LAG
Global PTP mode in main UI configures PTP boundary clock on the newly
formed Auto-LAG interface when it is enabled on the switch models that
support PTP boundary clock mode.
Workaround: Do
not enable Auto-LAG Global PTP mode from main UI if you do not use the PTP
boundary clock mode of operation and configure it manually on the newly formed
Auto-LAG interface.
- G&D
Control Center IP devices fail to link up with the switch.
Workaround:
Manually set the switch port speed to 1G to establish the link.
- This
firmware includes a configuration migration process that transitions the
default web browser protocol from HTTP to HTTPS. When you upgrade to this
firmware and import an older configuration with HTTPS disabled, HTTPS
becomes enabled.
Workaround:
Reconfigure the web browser protocol settings manually after you perform a
firmware upgrade or import an older configuration.
- During
your initial login, you must set up a password to access the switch.
However, if you access the main UI before you set up a password and
simultaneously set the password in the AV UI, the switch console might
lock for up to 15 minutes.
Workaround: Configure a password in either the main UI or the
AV UI to avoid this lock up issue.
- If you
upload only the private key or the certificate before you enable HTTPS,
the system enables the HTTPS service but it fails
to operate correctly because the configuration is incomplete. A factory
reset does not fix this issue.
Workaround:
Ensure both the private key and certificate are fully uploaded before you
enable HTTPS. If the issue still occurs, remove the incomplete HTTPS-related
private key or certificate, and disable HTTPS before reconfiguring.
- The four
25G ports of models M4350-44M4X4V, M4350-24X4V, and M4350-24F4V can
operate at either 10G or 25G speed but not simultaneously at 10G and 25G
speed.
- A
stacking link works only at the highest speed that the port supports. For
example, if you configure a 25G port in stack mode, the port can operate
only at 25G and not at 10G. Therefore, you cannot establish a stacking
link if a 10G port and a 25G port are interconnected.
Warnings:
Read and follow these warnings before updating your
firmware:
- HTTPS is
set to default web browser protocol from firmware version 14.0.6.10 and
newer versions. The default certificate is self-signed, so a browser
warning might display when you log in. To avoid
this warning, you can download your own certificate that is issued by a
trusted Certificate Authority (CA).
General Information:
- The boot
code remains at the existing version 1.0.0.15 in this switch firmware.
- The
process of upgrading the firmware and boot code takes about three minutes.
Apply the “update bootcode” command from the
command line interface. Do not switch off or restart the device during the
upgrade process.
- This
switch firmware upgrades AppMgr to version
1.0.6.16.
- Insight
and Engage/AV UI are mutually exclusive. This
means you can only use one of these options to configure and manage the
switch, not both.
- If the
encrypted password in the configuration file does not adhere to the
NETGEAR password policy, when the configuration file is loaded on the
firmware version 14.0.6.9 or later, you must create a new password during
the initial login.
Download Link: https://www.downloads.netgear.com/files/GDC/M4350/M4350_V14.0.6.19.zip
Firmware Checksum Details
File Name: M4350-v14.0.6.19.stk
MD5: 60227614CBFA7B4830077EF9B19C7CFB
SHA-256: d37f5859af12726944074336b2e0eac7e508e0e34086e69c733be55a99f7f715
Firmware Update Instructions:
To update your product’s firmware, follow the instructions
in your product’s user manual. To find your user manual, visit https://www.netgear.com/support/,
enter your model number in the search box, and click the Documentation button
on the product page.