Release Date:
October 22, 2025
Enhancements:
The AV UI provides the following enhancements:
- Support
for new AV profiles:
- Visionary
Advanced Multi-Domain
- G&D
KVM-over-IP
- Poly
StudioNet Modular Room
- URC
Automation
- Avid
S6L
- Updated
the default web browser protocol to HTTPS
- Added
interface descriptions that specify the VLAN ID, the profile name and the
profile template
- Updated
AV profile descriptions
- QoS is
redesigned on the related profiles
- Support
for gPTP options on all AVB profiles
- Support
for REST API:
- Saves
switch configuration
- Enables
or disables IGMP Plus
The firmware provides the following enhancement:
·
Updated the default web browser protocol to
HTTPS
Bug Fixes:
This firmware addresses the following bugs:
- Fixes
the issue where the SNMP access times out on a stack with 6 or more units.
[MS-3746]
- Fixes
the issue where the switch crashes when the configuration is cleared
immediately after switch is turned on. [MS-4448]
- Fixes
the issue where packets drop even though conditions do not match with the
outbound policy. [MS-4801]
- Fixes the issue where the AGM731F or AGM732F modules
connect the switch to another switch by setting a fixed 1G speed on the
SFP+ port, and the link does operate successfully after the switch
restarts. [MS-4862, CE-6806]
- Fixes
the issue where the switch crashes in a network loop condition. [MS-4867,
CE-6741]
- Fixes the issue where the switch crashes when protocol
logging is enabled and the Tech Support file is generated from the Main UI
or AVUI of the switch. [MS-4919]
- Fixes
the issue where the 224.0.1.129 PTP packet is not forwarded through the
stacking port. [MS-4953]
- Fixes
the issue where the IGMP querier does not elect correctly when MSTP is
configured. [CE-6738]
- Fixes the issue where the switch does not lease more
than 2000 IP addresses. [CE-6745]
- Fixes
the issue where AVB systems only with 100 MB capability do not synchronize
when they connect to certain ports. [CE-6848]
- Fixes
the issue where you cannot use the user name in
the password. [MS-5038]
- Fixes the issue where the MLD query packets flood in a large network. [CE-7028]
- Fixes
the issue where you can use insecure SSH key exchange (KEX) algorithms
“diffie-hellman-group-exchange-sha256” and “diffie-hellman-group14-sha1”
for secure connection. [CE-6562]
- Fixes
the issue where the switch does not respond when it connects through the
main UI, SSH, or serial console after you download the Tech Support file.
[CE-6900]
Known Issues:
This AV UI contains the following known issues:
- An Auto-LAG does not form after you apply
the G&D KVM-over-IP AV profile.
Workaround: Form the
Auto-LAG before you apply the G&D KVM-over-IP profile.
Additionally, apply the following
command to the LAG and trunk interfaces to enable G&D device discovery: macfilter adddest 01:0F:F4:00:00:00 <pvid>
This firmware contains the following known issues:
- Auto-LAG
Global PTP mode in main UI configures PTP boundary clock on the newly
formed Auto-LAG interface when it is enabled on the switch models that
support PTP boundary clock mode.
Workaround: Do not enable
Auto-LAG Global PTP mode from main UI if you do not use the PTP boundary clock
mode of operation and configure it manually on the newly formed Auto-LAG
interface.
- G&D
Control Center IP devices fail to link up with the switch
Workaround: Manually set the
switch port speed to 1G to establish the link.
- This
firmware includes a configuration migration process that transitions the
default web browser protocol from HTTP to HTTPS. When you upgrade to this
firmware and import an older configuration with HTTPS disabled, HTTPS
becomes enabled.
Workaround: Reconfigure the
web browser protocol settings manually after you perform a firmware upgrade or
import an older configuration
- During
your initial log in, you must set up a password to access the switch.
However, if you access the main UI before you set up a password and
simultaneously set the password in the AV UI, the switch console might
lock for up to 15 minutes.
Workaround: Configure a password in either the main UI or the
AV UI to avoid this lock up issue.
- If
you upload only the private key or the certificate before you enable
HTTPS, the system enables the HTTPS service but
it fails to operate correctly because the configuration is incomplete. A
factory reset does not fix this issue.
Workaround: Ensure both the
private key and certificate are fully uploaded before you enable HTTPS. If the
issue still occurs, remove the incomplete HTTPS-related private key or
certificate, and disable HTTPS before reconfiguring.
- The
four 25G ports of models M4350-44M4X4V, M4350-24X4V, and M4350-24F4V can
operate at either 10G or 25G speed but not simultaneously at 10G and 25G
speed.
- A
stacking link works only at the highest speed that the port supports. For
example, if you configure a 25G port in stack mode, the port can operate
only at 25G and not at 10G. Therefore, you cannot establish a stacking
link if a 10G port and a 25G port are interconnected.
Warnings:
Read and follow these warnings before updating your
firmware:
- HTTPS
is set to default web browser protocol from firmware version 14.0.6.10 and
newer versions. The default certificate is self-signed, so a browser
warning might display when you log in. To avoid
this warning, you can download your own certificate that is issued by a
trusted Certificate Authority (CA).
General Information:
- The
boot code remains at the existing version 1.0.0.15 in this switch
firmware.
- The
process of upgrading the firmware and boot code takes about three minutes.
Apply the “update bootcode” command from the
command line interface. Do not switch off or restart the device during the
upgrade process.
- AppMgr is upgraded to version 1.0.4.27 in this switch
firmware.
- Insight
and Engage/AV UI are mutually exclusive. This
means you can only use one of these options to configure and manage the
switch, not both.
- If
the encrypted password in the configuration file does not adhere to the
NETGEAR password policy, when the configuration file is loaded on the
firmware version 14.0.6.9 or later, you must create a new password during
the initial login.
Download Link: https://www.downloads.netgear.com/files/GDC/M4350/M4350_V14.0.6.13.zip
Firmware Checksum Details
File Name: M4350-v14.0.6.13.stk
MD5: 30E540CF6E2163BF69904DFB83490B04
SHA-256: 262B84A65E3C5AEDD3D37A4386800DCA3DE46AD72FC49AE95293576462ABC74E
Firmware Update Instructions:
To update your product’s firmware, follow the instructions
in your product’s user manual. To find your user manual, visit https://www.netgear.com/support/, enter
your model number in the search box, and click
the Documentation button on the product page.