Release Date:
April 29, 2026
Enhancements:
The AV UI provides the following enhancements:
- Added a
new AJA AV Network profile.
- Added a
new AUDAC Audio and Control Network profile.
- Added a
new BluOS AV profile.
- Added
Color Palettes to the profile color picker.
- Update
Nice Home Management profile with auto provision features.
Bug Fixes:
This firmware addresses the following bugs:
- Fixed an
issue where continuous DHCPv6 packet causes switches to reboot
unexpectedly. [CE-7265]
- Fixed an
issue where switches occasionally crash when setting up routing in a
specific sequence. [MS-5373]
- Fixed the
issue where creating a Tagged VLAN Port in an AVB
VLAN Profile incorrectly changes the MTU to 9198. [CE-7632]
- Fixed the
issue where PTP TC is not enabled on a manual LAG interface when using
Manual Trunk. [CE-7608]
- Fixed the
issue where the Audio Dante profile auto-trunk port retains “no spanning
tree port mode” configuration after connecting. [PV-6886]
- Fixed the
issue where AVUI rejects subnet mask 255.255.255.254 with an incorrect
subnet error. [CE-7650]
- Fixed the
issue where NVX profile cannot be applied to ports 25-48 of the secondary
switch in a stacked GSM4352PS configuration. [CE-7512]
- Fixed the
issue where PVST is disabled on a VLAN after deleting and re-creating a
DICENTIS Conference System profile on that VLAN. [CE-7469]
Known Issues:
This AV UI contains the following known issues:
- gPTP Clock Master Causes Time Drift with AVB MILAN
Devices If the switch becomes the gPTP clock
master, time drift issues may occur when AVB MILAN devices are in
use.
Workaround: When
creating an "Audio Video AVB MILAN" profile in AVUI, set the Local
Clock Priority 1 and Priority 2 values to 255 to prevent the switch from acting
as the clock master.
- Stale
Spanning Tree Configuration After Firmware Upgrade from AVUI 2.2.13.29
when upgrading firmware from AVUI 2.2.13.29 to the current release, access
port configurations with no spanning-tree port mode may persist. If
Dante devices are connected using redundancy ports, this can cause a
network loop.
Workaround: Manually
clear the stale configuration by setting the affected interfaces back
to spanning-tree port mode.
- Kramer AV
Single-VLAN Profile Cannot Be Modified When Using VLAN 1 If a Kramer AV
profile is created with a single VLAN and that VLAN is VLAN 1, the profile
cannot be modified to another single-VLAN profile.
Workaround:
Use a VLAN ID other than VLAN 1 when creating a single-VLAN Kramer AV profile.
This firmware contains the following known issues:
- After
you upgrade the firmware from 12.0.9.x to 12.0.11.x or a newer release,
when you use the main UI, and you select Routing > Multicast > Mroute Static-Multicast Configuration, the page
does not display automatically.
Workaround: After the firmware upgrade, clear your browser cache.
- When you
manually enable the Auto Negotiation through the CLI, it does not display
as “Enabled” in the AV UI.
Workaround: Configure and verify Auto Negotiation through the CLI.
- G&D
Control Center IP devices fail to link up with the switch
Workaround: Manually
set the switch port speed to 1G to establish the link.
Warnings:
Read and follow these warnings before updating your
firmware:
- For user
passwords, line passwords, and enable passwords that are encrypted with
AES in firmware release 12.0.15.7 or earlier releases, automatic migration
is supported to the more secure SHA512 in release 12.0.17.6 or later
releases.
- User
passwords, line passwords, and enable passwords that are encrypted with
MD5 (salted) in firmware release 12.0.15.7 or earlier releases are not
migrated to release 12.0.17.6 or later releases, so they must be set
manually.
- SNMPv3
MD5 and SHA-based passwords from firmware release 12.0.15.7 or earlier
releases are not migrated to release 12.0.17.6 or later releases, so they
must be set manually.
General Information:
- The boot
code remains at the existing version 1.0.0.18 in this switch firmware.
- The
process of upgrading the firmware and boot code takes about three minutes.
Apply the “update bootcode” command from the
command line interface. Do not switch off or restart the device during the
upgrade process.
- AppMgr is upgraded to version 1.0.6.16 in this switch
firmware.
Download Link: https://www.downloads.netgear.com/files/GDC/M4300/M4300_V12.0.19.21.zip
Firmware Checksum Details
File Name: M4300-v12.0.19.21.stk
MD5: 3D8DC7952550BB8FE8E207784CC01974
SHA-256: 416a6ecdf9f10526ce9203448b7d36f9b7b6d8958a896b0379f0f6b3d5a35f04
Firmware Update Instructions:
To update your product’s firmware, follow the instructions
in your product’s user manual. To find your user manual, visit https://www.netgear.com/support/, enter
your model number in the search box, and click the Documentation button
on the product page.