Release Date:
April 29, 2026
This firmware supports the GSM4230P, GSM4230PX, GSM4230UP, GSM4248P,
GSM4248PX, and GSM4248UX models.
Enhancements:
The AV UI provides the following enhancements:
- Support
for new AJA AV Network profile.
- Support
for new Audio Video AVB MILAN profile.
- Support
for new Audio Video AVB MILAN with Dante PTPv1 PTPv2 or AES67 profile.
- Support
for new AUDAC Audio and Control Network profile.
- Support
for new BluOS AV profile.
- Support
for Color Palettes to the profile color picker.
- Update
Nice Home Management profile with auto provision features.
Bug Fixes:
- Fixes
the issue where only five Auto-LAGs were created even when more than five
devices were connected using multiple links per device. [MS-5200]
- Fixes
the issue where continuous DHCPv6 packets cause switches to reboot
unexpectedly. [CE-7265]
- Fixes
the issue where the switch operates as dot1AS Grand Master sent Announce
messages with a UTC Offset value of 0. [MS-5416]
- Fixes
the issue where OUI-based VLAN assignments stopped functioning after
extended operation. [CE-7316]
- Fixes
the issue where the VLAN 1 routing interface could not be removed through
the Main UI. [CE-7321]
- Fixed
the issue where creating a Tagged VLAN Port in an
AVB VLAN Profile incorrectly changes the MTU to 9198. [CE-7632]
- Fixes the issue where PTP TC is not enabled on a manual
LAG interface when using Manual Trunk. [CE-7608]
- Fixes
the issue where the Audio Dante profile auto-trunk port retains “no
spanning tree port mode” configuration after connecting. [PV-6886]
- Fixes
the issue where AVUI rejects subnet mask 255.255.255.254 with an incorrect
subnet error. [CE-7650]
- Fixes
the issue where PVST is disabled on a VLAN after deleting and re-creating
a DICENTIS Conference System profile on that VLAN. [CE-7469]
- Fixes
the issue where Voice VLAN configuration on a port was unexpectedly
disabled after re-enabling Insight management. [CE-7582]
- Fixes
the issue where VLAN 1 membership unexpectedly changed to tagged after
activating Insight management. [CE-7601]
AV UI Known Issues:
- gPTP Clock Master Causes Time Drift with AVB MILAN
Devices:
If the switch becomes the gPTP clock master,
time drift issues may occur when AVB MILAN devices are in use.
Workaround: When creating an "Audio Video AVB MILAN"
profile in AVUI, set the Local Clock Priority 1 and Priority 2 values to
255 to prevent the switch from acting as the clock master.
- Stale
Spanning Tree Configuration After Firmware Upgrade from AVUI 2.2.13.29:
When upgrading firmware from AVUI 2.2.13.29 to the current release, access
port configurations with no spanning-tree port mode may persist. If Dante
devices are connected using redundancy ports, this can cause a network
loop.
Workaround: Manually clear the stale configuration by setting the
affected interfaces back to spanning-tree port mode.
- Kramer
AV Single-VLAN Profile Cannot Be Modified When Using VLAN 1:
If a Kramer AV profile is created with a single VLAN and that VLAN is VLAN
1, the profile cannot be modified to another single-VLAN profile.
Workaround: Use a VLAN ID other than VLAN 1 when creating a
single-VLAN Kramer AV profile.
Firmware Known Issues:
- This
firmware includes a configuration migration process that transitions
default web browser protocol from HTTP to HTTPS. When you upgrade to this
firmware and import an older configuration with HTTPS disabled, HTTPS
becomes enabled.
Workaround: Reconfigure the web browser protocol settings manually
after you perform a firmware upgrade or import an older configuration
- During
your initial log in, you must set up a password to access the switch.
However, if you access the main UI before you set up a password and
simultaneously set the password in the AV UI, the switch console might
lock for up to 15 minutes.
Workaround: Complete the password setup in only one GUI interface
to avoid this lock up issue.
- If you
upload only the private key or the certificate before you enable HTTPS,
the system enables the HTTPS service but it fails
to operate correctly because the configuration is incomplete. A factory
reset does not fix this issue.
Workaround: Ensure both the private key and certificate are fully
uploaded before you enable HTTPS. If the issue still occurs, remove the
incomplete HTTPS-related private key or certificate, and disable HTTPS
before reconfiguring.
Warnings:
Read and follow these warnings before updating your
firmware:
- SNTP
is deprecated from firmware version 13.0.5.10 onwards and NTP is
introduced. Configure an NTP server in your network. Remove SNTP related
settings from the configuration file on firmware version 13.0.4.x before
you apply it to the switch running firmware version 13.0.5.x.
- HTTPS
is set to default web browser protocol from firmware version 13.0.5.20 and
newer versions. The default certificate is self-signed, so you may
encounter a browser warning when logging in. To avoid this warning, you
can download your own certificate issued by a trusted Certificate
Authority (CA).
General Information:
- The
boot code remains at the existing version 1.0.0.13 in this switch
firmware.
- The
process of upgrading the firmware and boot code takes about three minutes.
Apply the “update bootcode” command from the
command line interface. Do not switch off or restart the device during the
upgrade process.
- The
switch firmware upgrades AppMgr to version
1.0.6.16.
- Insight
and Engage/AV UI are mutually exclusive. This
means you can only use one of these options to configure and manage the
switch, not both.
- If the
encrypted password in the configuration file does not adhere to the
NETGEAR password policy, when the configuration file is loaded on the
firmware version 13.0.5.16 or later, you must create a new password during
the initial login.
Download Link: https://www.downloads.netgear.com/files/GDC/M4250W2/GSM4230xx_GSM4248xx_V13.0.5.26.zip
Firmware Checksum Details
File Name: M4250H-v13.0.5.26.stk
MD5: 941C1F5AAC814E8679FC8C97E7242270
SHA-256: 6b4b97f800316a310a7651bab44930e4c6f3924862117417ac746a24b9d19da9
Firmware Update Instructions:
To update your product’s firmware, follow the instructions
in your product’s user manual. To find your user manual, visit https://www.netgear.com/support/, enter
your model number in the search box, and click the Documentation button
on the product page.