Bug Fixes:
- Addresses the following security vulnerability issues published on CVE web site https://cve.mitre.org/:
CVE-2011-3389,
CVE-2009-3555
CVE-2013-2566
CVE-2015-2808
Note: For CVE-2011-3389 case, we need to disable TLSv1 protocol (under Security > Access > HTTPS> HTTPS Configuration). Since GS510TP supports only SSLv3 and TLSv1, any legacy client supporting only TLSv1 may not establish the SSL connection with the switch. So, the best way is to disable the TLSv1 mode and when required for legacy clients the mode can be enabled again. However, enabling the mode will be prone to CVE-2011-3389.
- Fixed the issue where the EAP packet with unicast destination address is blocked when “EAPOL Flooding mode” is enabled while “802.1X admin mode” is disabled.
- Fixed the issue where the system freezes when downloading HTTPS/SSL certificate file (server.pem) to the switch.
- Fixed the issue where the flash logs disappear after system reboot.
- Removed “Refresh” button from FLASH log page.
- Fixed the issue where the following optional TLV values of LLDP-MED are incorrect:
Optional Mau Type
Auto-negotiation advertised capability
Maximum Frame size
Asset ID
Manufacturer name
Firmware and Hardware revision
- Fixed the port security issue with static MAC. When a static MAC address is specified and the “Max Allowed Dynamically Learned MAC” is set to 0 for a port, this MAC address can still be learned by other ports. As a result, device with this MAC can work with other ports with “Max Allowed Dynamically Learned MAC” not set to 0, but not with the port with static MAC configured.
Known issues:
- Port PVID (Switching > VLAN > Advanced > Port PVID Configuration) does not automatically changed back to 1 after its associated VLAN is deleted.
Workaround: Manually change the PVID back to 1.
Limitations:
- Combined MAC and IP ACL do not work with double VLAN tagged traffic.
Upgrade Instructions:
This product includes software code developed by third parties, including software code subject to the GNU General Public License ("GPL") or GNU Lesser General Public License ("LGPL"). As applicable, the terms of the GPL and LGPL, and information on obtaining access to the GPL Code and LGPL Code used in this product, are available to you at NETGEAR's Open Source Code Web page. The GPL Code and LGPL Code used in this product is distributed WITHOUT ANY WARRANTY and is subject to the copyrights of one or more authors. For details, see the GPL Code and LGPL Code for this product and the terms of the GPL and LGPL.